Performance Data – MWM Gas Engine TCG 2020 /
TCG 2020 K
Natural gas applications, NOx ≤ 500 mg/Nm3 *
TCG 2020 V12
RW = Optimized for high total efficiency at requested powerEngine type50 HzElectrical outputkW1000Thermal output ± 8%kW1056Electrical efficiency%43.0Thermal efficiency%45.4Total efficiency%88.4Power to heat ratio **0.95TCG 2020 V12 K
K = Optimized for robustness and low CAPEXTCG 2020 V12
R = Optimized for high total efficiencyEngine type50 Hz60 Hz50 Hz60 HzElectrical outputkW1125112512001200Thermal output ± 8%kW1251126211891196Electrical efficiency%41.040.743.743.4Thermal efficiency%45.645.643.343.2Total efficiency%86.686.387.086.6Power to heat ratio **0.900.891.001.00TCG 2020 V16 K
K = Optimized for robustness and low CAPEXTCG 2020 V16
R = Optimized for high total efficiencyEngine type50 Hz60 Hz50 Hz60 HzElectrical outputkW1500150015601560Thermal output ± 8%kW1675168615761589Electrical efficiency%40.940.643.343.0Thermal efficiency%45.745.743.843.8Total efficiency%86.686.387.186.8Power to heat ratio **0.890.890.990.98TCG 2020 V20
R = Optimized for high total efficiencyTCG 2020 V20
P = Optimized for high electrical efficiencyEngine type50 Hz60 Hz50 HzElectrical outputkW200020002000Thermal output ± 8%kW198319971912Electrical efficiency%43.743.444.4Thermal efficiency%43.343.342.5Total efficiency%87.086.786.9Power to heat ratio **1.011.001.04
* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
Biogas, Landfill Gas, and Sewage Gas Applications, NOx ≤ 500 mg/Nm3 *
TCG 2020 V12
XW = Optimized for operation with biogases at requested powerTCG 2020 V12
X = Optimized for operation with biogasesEngine type50 Hz50 Hz60 HzElectrical outputkW100012001200Thermal output ± 8%kW103511921201Electrical efficiency%42.643.042.7Thermal efficiency%44.142.742.7Total efficiency%86.785.785.4Power to heat ratio **0.971.001.00
TCG 2020 V16
X = Optimized for operation with biogasesTCG 2020 V20
X = Optimized for operation with biogasesEngine type50 Hz60 Hz50 Hz60 HzElectrical outputkW1560156020002000Thermal output ± 8%kW1566158020102024Electrical efficiency%42.742.343.042.7Thermal efficiency%42.942.843.243.2Total efficiency%85.685.186.285.9Power to heat ratio **1.000.991.000.99
* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
Specifications and Service Intervals –
MWM Gas Engine TCG 2020 / TCG 2020 K
Dimensions and Weights
TCG 2020 V12
RW = Optimized for high total efficiency at requested power
XW = Optimized for operation with biogases at requested powerEngine type50 HzLengthmm4660Widthmm1810Heightmm2210Dry weight gensetkg11200Bore / strokemm170/195Displacementdm353.1Speedmin-11500Mean piston speedm/s9.8
TCG 2020 V12 K
K = Optimized for robustness and low CAPEXTCG 2020 V12
R = Optimized for high total efficiency
X = Optimized for operation with biogasesEngine type50 Hz60 Hz50 Hz60 HzLengthmm4790597047905970Widthmm1810179018101790Heightmm2210221022102210Dry weight gensetkg11700130001170013000Bore / strokemm170/195170/195170/195170/195Displacementdm353.153.153.153.1Speedmin-11500150015001500Mean piston speedm/s9.89.89.89.8
TCG 2020 V16 K
K = Optimized for robustness and low CAPEXTCG 2020 V16
R = Optimized for high total efficiency X = Optimized for operation with biogasesEngine type50 Hz60 Hz50 Hz60 HzLengthmm5430664054306640Widthmm1810179018101790Heightmm2210221022102210Dry weight gensetkg13300149001330014900Bore / strokemm170/195170/195170/195170/195Displacementdm370.870.870.870.8Speedmin-11500150015001500Mean piston speedm/s9.89.89.89.8
Email : bulbulbasher@gmail.com
Facebook https://www.facebook.com/bulbul.basher
Linkedin
https://www.linkedin.com/in/md-bulbul-basher-373579181
https://www.facebook.com/জামালপুর-ইন্জিনিয়ার্স-এসোসিয়েশন্স-605960969556347/
0 Comments